Steam & Sauna Buyer's Club

 

Title
GENERATOR, 14.1KW 240V

Amerec AX14

AX Series 14.1KW Steam Bath Generator

Model
MS225E

The Amerec AX14 steam bath generator from the AX Series boasts a 14.1 kilowatt power rating and is made for home steam baths with dimensions between 350 to 550 adjusted cubic feet. 

Internal Notes
  • 12/15/16: Per Pat Smith - can be wired for 1PH or 3PH in the field, not factory. Only the AX can be wired this way.
  • 4/27/17: warm start included and only works with A6 control. If connecting generators to accommodate a larger room size, you need to purchase a tandem cable 5304-030 and use an additional steam head, autodrain, plumbing fittings, etc. just like we used to on systems like AK30. Warm start cable is sold separately 8855-139. Order in 240V or 208V and field wire for 1PH or 3PH
  • Warm Start feature standard
  • Stainless steel tank
  • Industrial grade, serviceable heating elements
  • Durable electronic components
  • Electronic water-level control system
  • Low voltage safety control circuits
  • Electrical can be wired for 1-phase or 3-phase in the field
  • Available Auto Drain automatic draining system
  • Optional tandem operation for room size greater than 550 cu ft (requires purchase of a tandem cable)
  • Operates with inside/outside shower, on/off, time/temperature controls
  • Full 3/4" port drain valve
  • ASME safety valve
  • UL/CSA/CE listed
  • Steam bath generator
  • Control Cable 50' 4-wire CAt5
  • Sensor cable 50' 2-conductor
  • Installation and operation manual
  • Limited warranty
Swipe horizontally to reveal full table content.
Model AX14
Minimum Adjusted Cubic Feet 350
Maximum Adjusted Cubic Feet 550
Shipping Weight 32 lbs
Swipe horizontally to reveal full table content.
Electrical 240V/1PH 240V/3PH 208V/1PH 208V/3PH
Kilowatt Rating 14.00 KW 14.00 KW 13.58 KW 13.58 KW
AC Voltage 240V AC 240V AC 208V AC 208V AC
DC Voltage 5V DC 5V DC 5V DC 5V DC
Phase 1PH 3PH 1PH 3PH
Nominal Amperage 2 Circuits, 21 and 38 Amps Respectively 34 Amps 2 Circuits, 24 and 42 Amps Respectively 38 Amps
Recommended Protective Device 2 Circuits, 30 and 50 Amps Respectively 50 Amp 2 Circuits, 30 and 50 Amps Respectively 50 Amps
Swipe horizontally to reveal full table content.
Water Supply Connection 3/8" NPT
Generator Steam Line Connection 1/2" NPT
Steam Head Connection 1/2" NPT
Drain Connection 3/4" NPT
Safety Relief Valve Connection 3/4" NPT
Safety Relief Valve 10 PSIG
Control "Rough-In" Cut-Out 2-3/8" Diameter
Control Sensor Cable 25', 2 Conductor, 22 AWG, Shielded Cable
Control Sensor "Rough-In" Cut-Out 7/8" Diameter
Generator Control Connection 8 Pin, Snap-In Connector
Generator Control Cable 25', 8 Conductor, 28 AWG, Shielded Cable
Width 16-1/2"
Depth 6-1/4"
Height 15"